First things first, what equipment will the generator be running?
Make a list of everything you need to power and add up the total wattage.The total wattage will tell you the amount of electrical power required by your equipment and from there you can work out the minimum electrical input needed from a generator.
For more information, please visit 30 kw perkins generator.
You can find wattage information either on the equipments silver nameplate or in the manufacturers guide.
NB. Some electrical equipment has a different starting and running wattage. This is because it takes more energy to start equipment with an electric motor than it does to keep the motor running. It is vital that any initial surge in wattage is factored into the generator sizing process: its no use having a generator that matches your running requirements but doesnt have enough power to start the load.
A commercial generator plays a critical role in your business continuity plan. By providing backup or emergency power to your building during a power outage, commercial standby generators enable critical facilities like elevators and security systems to continue operating. Standby generators also minimize business and data losses that arise from computer system failures.
However, determining how to properly size a generator depends on a number of factors. Before you proceed with your commercial generator purchase, youll need to consider the needs of your business and the technical constraints of your building first.
Commercial backup generators provide power to a number of critical safety systems that operate during an emergency, including fire alarms, fire pumps, security systems, and emergency lighting. Different buildings require different levels of backup power to keep these life-saving systems operational in the event of a blackout.
This is why most large-scale commercial generator installations require an engineering plan and an engineers supervision to ensure compliance with National Electrical Code (NEC) and National Fire Protection Association (NFPA) requirements in the United States. Beyond regulatory compliance, not knowing how to properly size a generator can also lead to a host of other problems.
Lets look at what you need to know about estimating the right sized generator for your business.
Start with making a list of everything that you plan to power with your backup generator. This varies widely depending on what type of business you operate, so dont make the mistake of glossing over this step too quickly.
Some factors for sizing a commercial generator include selecting single- or three-phase power, voltage selection and total power output. Be aware that most commercial applications require a reserve or surge capability, especially for large motors operated by several units independently.
Once you know which items you need to power with your generator, you will need to estimate your businesss power consumption at peak usage. Depending on the type of business and your power needs, there are a variety of methods you can use to determine your full load capacity.
Full load kW = Total amps x supply voltage / 1,000
Reserve capacity = Full load kW x 0.25
Are you interested in learning more about Cummins Diesel Generator Price? Contact us today to secure an expert consultation!
For 100 percent power, generator size = Full load kW + reserve capacity
Utilize your utility company's billing system to find your maximum power usage.
The square footage sizing method is commonly used for retail locations such as grocery stores, restaurants and convenience stores.
Retail application: 50 kW + 10 watts per square foot
Other commercial application: 50 kW + 5 watts per square foot
In addition to estimating your total power needs, it is critical to determine the starting load and running load for each item.
For backup use, you can calculate the load on a staggered start for multiple units to spread out the load. Use the highest Locked Rotor (LR) rating from of all the items you want to run.
If you can't determine the running watts of an item, use the formula of watts = volts x amperes. Only motor-driven items have an additional starting voltage requirement. Remember: For accurate sizing, convert all amps to kilowatts.
Once you have calculated the amount of power you will need from a commercial backup generator, the next step is to identify a generator unit that will meet your needs. To help guide your selection, manufacturers offer performance charts for each product they sell.
First, look for a unit with the necessary power rating to run each of your selected items. Generators are usually rated in kilowatts and come in a wide variety of capacities. If your needs fall between common ratings, choose the next highest capacity.
To avoid the pitfalls that come with not knowing how to size a generator, consider seeking out the assistance of a backup power expert. General Power is here to help you find the right generator for your specific needs.
Our power experts will partner with you to understand your needs and help you select the right unit for your business. Call 1-888-819- to speak to one of our friendly staff members.
Contact us to discuss your requirements of 250kw generator. Our experienced sales team can help you identify the options that best suit your needs.